BNDXW - 97-725 EPOXY THINNER

  • MSDS: BNDXW
  • Manufacturer: PPG INDUSTRIES INC
  • Product Name: 97-725 EPOXY THINNER
  • National Stock Number: 8040-00F022237
Product Identification

Product ID:97-725 EPOXY THINNER
MSDS Date:02/26/1991
FSC:8040
NIIN:00F022237
MSDS Number: BNDXW

Responsible Party
PPG INDUSTRIES INC
4325 ROSANNA DR
ALLISON PARK, PA 15101
US

Emergency Phone: (412) 492-5555

Info Phone: (412) 492-5555

Cage: DO542

Contractor
PPG INDUSTRIES INC. COATINGS & RESINS GP
9 ALLISON PARK, PA 15101

Telephone: 412-492-5555

Cage: DO542

Ingredients

ISOPROPANOL (ISOPROPYL ALCOHOL), 2-PROPANOL, DIMETHYL

CAS: 67-63-0

RTECS: NT8050000

Fraction By Weight: 5-10%

OSHA PEL 400 PPM

ACGIH TLV: 400 PPM


ETHYLENE GLYCOL PROPYL ETHER, EKTASOLVE EP

CAS: 2807-30-9

RTECS: KM2800000

Fraction By Weight: 25-30%


TOLUENE (SARA III)

CAS: 108-88-3

RTECS: XS5250000

Fraction By Weight: 15-20%

OSHA PEL 200 PPM/150 STEL

ACGIH TLV: 50 PPM; 9293

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


XYLENE, DIMETHYLBENZENE, XYLOL

CAS: 1330-20-7

RTECS: ZE2100000

Fraction By Weight: 40-45%

OSHA PEL 100 PPM

ACGIH TLV: 100 PPM, SKIN

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


7.25

RTECS: 9999999WG

Hazards

Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INGESTION: HARMFUL & FATAL. EYES/SKIN:
IRRITATION. INHALATION: HARMFUL, FATAL, IRRITATION OF THE THROAT,
RESPIRATORY SYSTEM, PERMANENT BRAIN & NERVOUS SYSTEM DAMAGE.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:INGESTION: HARMUL & FATAL. EYES/SKIN:
IRRITATION. INHALATION: HARMFUL, FATAL, IRRITATION OF THE THROAT,
RESPIRATORY SYSTEM, PERMANENT BRAIN & NERVOUS SYSTEM DAMAGE.

First Aid

First Aid:INGESTION: DON'T INDUCE VOMITING. EYES: FLUSH W/PLENTY OF
WATER FOR 15 MIN. SKIN: FLUSH W/PLENTY OF WATER & WASH W/SOAP.
INHALATION: REMOVE TO FRESH AIR & APPLY ARTIFICIAL RESPIRATION &
OTHER SUPPORTI VE MEASURES AS REQUIRED. OBTAIN MEDICALATTENTION IN
ALL CASES.

Fire Fighting

Flash Point Method:PMCC
Flash Point:59F
Lower Limits:1.3
Extinguishing Media:USE NFPA CLASS B EXTINGUISHERS DESIGNED TO
EXTINGUISH NFPA CLASS IB FLAMMABLE LIQUID FIRES.
Fire Fighting Procedures:WATER SPRAY MAY BE INEFFECTIVE. WATER SPRAY
CAN BE USED TO PREVENT PRESSURE BUILD-UP/POSSIBLE AUTOIGITION OR
EXPLOSION WHEN EXPOSED TO EXTREME HEAT.
Unusual Fire/Explosion Hazard:KEEP CONTAINERS CLOSED. CLOSED CONTAINERS
MAY EXPLODE WHEN EXPOSED TO EXTREME HEAT. TOXIC GASES MAY FORM IF
CONTACTED BY FLAME OR HOT SURFACES.

Accidental Release

Spill Release Procedures:VENTILATE & REMOVE ALL SOURCES OF IGNITION.
TAKE UP W/SAWDUST, VERMICULITE, OR OTHER ABSORBENT MATERIAL & PLACE
INTO CONTAINER. PERSONNEL W/PROPER EQUIPPED RESPIRATORY SHOULD BE
PERMITTED IN THE AREA.

Handling

Handling and Storage Precautions:DON'T STORE >120F. STORE LARGE
QUANTITIES IN BUILDINGS DESIGNED & PROTECTED FOR STORAGE OF NFPA
CLASS IB FLAMMABLE LIQUIDS.
Other Precautions:CONTAINERS SHOULD BE GROUNDED WHEN POURING. AVOID
FREE FALL OF LIQUIDS IN EXCESS OF A FEW INCHES.

Exposure Controls

Respiratory Protection:ENSURE VAPOR EXHAUST OR FRESH AIR ENTRY. USE
NIOSH/MSHA-APPROVED (TC-23C-) PAINT SPRAY OR AIR SUPPLIED (TC-19C-)
RESPIRATORS TO REDUCE EXPOSURE.
Ventilation:GENERAL DILUTION OR LOCAL EXHAUST
Protective Gloves:IMPERMEABLE
Eye Protection:SPLASH GOGGLES /FULL FACE SHIELD
Work Hygienic Practices:CLEAN OR DISCARD CONTALMINATED CLOTHING OR
SHOES.
Supplemental Safety and Health
BOILING RANGE: 180-307F

Chemical Properties

Boiling Pt:B.P. Text:SEE SUPP
Vapor Pres:11.2 MM HG
Vapor Density:>AIR
Spec Gravity:.87
Evaporation Rate & Reference:105
Solubility in Water:37.6%
Appearance and Odor:NON-VISCOUS LIQUID W/CHARACTERISTIC ODOR.
Percent Volatiles by Volume:100.0

Stability

Stability Indicator/Materials to Avoid:YES
STRONG ALKALIES, STRONG MINERAL ACIDS, & STRONG OXIDIZING.
Stability Condition to Avoid:HEAT, ELECTRICAL EQUIPMENT, SPARKS, & OPEN
FLAMES.
Hazardous Decomposition Products:HAZARDOUS WHEN HEATED, INCLUDING: CO.

Disposal

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE W/LOCAL, STATE, &
FEDERAL REGULATIONS. RECYCLE OR DISPOSE EMPTY CONTAINERS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.